Applicable standards:Automotive seat belt locking performance tester mainly meets the following nati
Электронная почта: info@standard-groups.com
Применимые критерии:
Automotive seat belt locking performance tester mainly meets the following national or industry standards:
GB 14166-2013 Seat belts, restraint systems, Child restraint Systems and ISOFIX Child Restraint Systems for Motor Vehicle Occupants
GB 27887-2011 Restraint System for Child Occupants of Motor Vehicles
Основные параметры:
Система управления:
PLC control system is usually used to realize automatic control and data processing.
Интерфейс операции:
It is equipped with a color touch screen and supports switching between Chinese and English for easy operation.
Emergency lock test parameters:
After installation, the winder can reach a speed of 2.94m/s within 50ms to simulate the locking function in emergency situations.
Angle adjustment:
The installation Angle can be adjusted, such as the winding shaft to the horizontal plane of 45°, 90°, 135° and 180° to adapt to different test requirements.
Vehicle acceleration adjustment range:
The acceleration adjustment range is usually 0.2——1.5g (can be set) to meet the needs of different test conditions.
Acceleration adjustment step:
The acceleration adjustment step is usually less than or equal to 0.05g to ensure the accuracy of the test.
Maximum displacement of car feeling:
The maximum displacement of the car is usually 100mm, which is used to simulate the displacement of the vehicle during an emergency stop or collision.
Inductive acceleration adjustment range:
The inductive acceleration adjustment range is not less than 0.2——2.5g to adapt to the test needs of different seat belt materials.
Acceleration measurement accuracy:
The measurement accuracy of acceleration is usually less than 0.01g to ensure the accuracy of the test results.
Repeatability deviation of acceleration:
The repeatability deviation of acceleration is usually less than or equal to ±0.01g to ensure the stability and reliability of the test results.
Maximum overshoot of acceleration:
The maximum overshoot of the acceleration is usually less than 10% of the set acceleration value to ensure the accuracy of the test.
Seatbelt locking distance measurement accuracy:
Seat belt lock distance measurement accuracy is usually less than or equal to ±0.01mm, to ensure the accuracy of the test results.
Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.