Thermal contact resistance tester evaluates welder gloves' protection.
WhatsApp: +86 13816217984
Email: info@qinsun-lab.com
Thermal contact resisting testing device is designed with the adoption of advance technology for testing the thermal contact resistance of welder’s gloves which are used for protecting hands and wrists in the operation process of welding and other related work.
Технические параметры
1、Heating unit contact surface diameter:(25.2±0.05)mm;
2、Calorimeter test surface diameter:(25±0.05)mm;
3、Contact force: (49±0.5)N;
4、Timer: 0~99.99s,Accuracy: ±0.01s;
5、Contact speed:95.0±0.2)mm/s ;
6、Sample size:diameter 80mm;
Стандарты
AQ 6103-2007 Protective gloves for welders. Appendix E Testing method for thermal contact resistance.
Характеристики
1.The heating unit is able to withstand a temperature up to 500℃,and the temperature is controllable.
2. Specially customized calorimeter meets test precision requirements.
3. Digital display the heating unit temperature, calorimeter temperature, critical time;
4. Contact speed is adjustable.
Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.