Temperature Oxygen Index Apparatus, ISO4589-3, Nes 715 - Qinsun
Специализированные производители контрольно - измерительных приборов
Национальная & quot; горячая линия & quot;:+86 021-64208466
Продукты

Temperature Oxygen Index Apparatus, ISO4589-3, Nes 715

Introduction:Temperature Oxygen IndexApparatus belongstoantiflamingtest equipment for measurin

WhatsApp +86 13816217984

Электронная почта :info@qinsun-lab.com

Содержание

Введение:

Temperature Oxygen IndexApparatus  belongstoantiflamingtest equipment for measuring the combustion performance of the vertical bars or  10.5mmthin  plasticmaterial under test conditions.Itis also suitable for combustion performance of vertical supporting film or thin filmmaterials .

Стандарты:

ISO4589-3: 1996 "oxygen index burning plastic behavior of high-temperature test measurement"

BS2782 Part 143.ASTM D 2863

ASTM 2863

Ницца 715

Instrument characteristics

1. The combustion cylinder with a heating element and a preheater. the temperature ofcombustioncylinderAdjustable .

2. The computerautomatically  controlsthe entiretest  process. The operator inputs the oxygen concentrationvalue  fromthe keyboard based on the test requirements. The instrument can automatically adjust the oxygen concentration value in the rangeof  setting.

3. Direct detection and display of oxygen concentration value in the sample chamber.

4. Automatic ignition is safe andreliable .

5. The computer automatically handles each set of testdata,and the determining reliability of the testdata  .

Технические нормы

1.Test temperature range: 25 ºC ~ 150 ºC;

2. The accuracy of the testtemperature  :≤125 ºC  ± 2 ºC;> 125 ºC ± 3 ºC

3. The oxygen concentration setting range: oxygen concentration value l0% ~ 60% (± 0.1%);

4.Theflow of oxygen, nitrogen  can be controlled at the set value; the control precision: ± 0.01L / min, Resolution: 0.01L / min;

5. The oxygen concentration stepsize :  it can be set from 0.1%;

6. The combustion time: 1 second to 300 seconds;

7. The ignition flame height: 15 to 20 mm adjustable;

8. The ignition timing: 15s ± 1s;

9. The quartz glass burner tube dimensions: internal  cylinder(inner diameter ≥75mm, height ≥450mm); outer tube ( the clearance between inner cylinder is  5mm ~ 10mm, the same height as theinternal  cylinder).

Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.


Онлайн сообщение

Контактные данные

Телефон компании

+86-21-6420 0566

Время работы

С понедельника по пятницу

Мобильный телефон:

13816217984

Электронная почта:

info@qinsun-lab.com

QR-код