Detailed Product DescriptionBrand:STDStandard:5208D,ISO 1523.ISO 3679Flash Point Detection Rang

WhatsApp +86 13816217984

Электронная почта :info@qinsun-lab.com

Содержание

Detailed Product Description

Brand:STDСтандарты:5208D,ISO 1523.ISO 3679
Flash Point Detection Range::(-20 ~ +100) ° CRelative Humidity:(30~80)%
Ambient Temperature:5 ° C ~ 30 ° CTemperature Control Accuracy:± 0.5 ° C
Power:AC220V ± 10%, 50HzKeywords:Oil Analysis Testing Equipment
Highlight:

oil analysis equipment

oil analysis machine

Product Introduction 

1. Full automatic closed cup flash point tester, used to measure the closed mouth flash point value of petroleum products.

2. Using 8-inch pure industrial true color touch screen, the Chinese and English interface can be switched at will,

3. Automatically correct the effect of atmospheric pressure on the test and calculate the correction value.

4. The lower computer stores 120 sets of historical data.

5. Ignition, printing, fully automatic.

6. Using imported Renesas MCU. Germany imported PT1000 high precision temperature sensor.

7. Built-in high-precision flash point detection sensor, detection time can reach milliseconds.

8. Simulation tracking shows the temperature rise as a function of test time,

Приложение

This instrument is especially suitable for testing the flash point of closed cups for various colored paints, paints, adhesives, solvents, petroleum and related products with a flash point in the range of -20 ℃ ~ + 80 ℃.

Технические параметры

1. Working power: AC220V ± 10%, 50Hz;

2. Flash point detection range: (-20 ~ +100) ° C;

3. Measurement precision: The absolute difference between the two experimental results is less than 2 °C (same operator);

The absolute difference between the two experimental results is less than 3 ° C (different operators);

4. Temperature control accuracy: ± 0.5 ° C;

5. Lgnition device: electronic ignition gun ignition;

6. Cooling method: semiconductor refrigeration (external cold water circulator);

7. The power supply voltage: AC220V ± 10%, 50Hz;

8. Power consumption of the whole machine: no more than 300W;

9. The ambient temperature: 5 ° C ~ 30 ° C;

10. Relative humidity: (30~80)%.

Характеристики

(1) Designed in accordance with GB / T 5208 "Determination of Flash Point, Quick Balance Closed Cup Method", to achieve the purpose of fast and low temperature test of closed cup flash point

(2) Using semiconductor refrigeration devices and external cooling water cooling devices, the instrument is small in size, fast in cooling speed and easy to use.

(3) There are few test samples, and only 2 ml is required for each injection (4 ml for solid or semi-solid samples).

(4) Except for ignition, the test process is completed automatically and the test results are printed automatically.

Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.