Environment Friendly 1260 L High And Low Temperature Test Chamber

StandardsGB / T2423.22-87Nb GJB1032-90 MIL-STD-2164 / (E / C)GB / T2423.4-93 GB / T2423.34-86 G

WhatsApp +86 13816217984

Электронная почта :info@qinsun-lab.com

Содержание

Стандарты

GB / T2423.22-87Nb GJB1032-90 MIL-STD-2164 / (E / C)

GB / T2423.4-93 GB / T2423.34-86 GJB150.9-86

Структура

The whole structure, that is, test box, refrigeration system, air conditioning system, electrical control cabinet, refrigeration unit as a whole, the refrigeration unit is located in the bottom of the box, electrical control part of the side of the test chamber, easy to operate.

2 The box:

A) the end of the studio in the duct sandwich, the distribution of heaters, refrigeration evaporator, blast motor, fan and other devices;

B) The test box side with a cable threading hole 1. size ф50mm;

C) The test chamber is made of 1mm thick SUS304 stainless steel plate. The box shell is made of 1mm thick cold plate

D) insulation material using polyurethane foam, thickness 100mm, good insulation effect, the outer surface of the test chamber does not frost, do not condensation.

E) The studio is equipped with four adjustable mesh partitions; each size 1400 (length) * 600 (width) * 375 (high), 4 layers

F) The tank is provided with a condensate drain.

3 The door:

Double door, door seals are used double-wire silicone rubber seal;

4 Observation lighting device:

The door is equipped with a multi-layer insulating glass observation window, the size of about: 300 × 275mm, and a heated anti-frost device. A (AC12V) 20W halogen lamp is installed on the door of the test chamber.

Main Specifications

 Interior size 600 × 1400 × 1500mm (depth × width × height)
 External Dimensions 1100 × 1800 × 2300mm (depth × width × height)
 The temperature range 0 ℃ ~ +30 ℃
 The temperature fluctuation ≤ ± 1 ℃v
 The temperature uniformity ≤ ± 3 ℃
 The temperature deviation ≤ ± 1 ℃
 The rise and fall rate Cooling rate RT ~ 0 ℃, average 1 ℃ / min non-linear
Heating rate of 0 ~ +30 ℃, an average of 3 ℃ / min non-linear
 Wind speed

 1.7 ~ 2.5m / s

The above indicators are in the ambient temperature ≤ 25 ℃, atmospheric pressure, no load, no load conditions, from the box wall within 1/6 space measured test;

 Power about 5.5Kw
 Power supply 380V ± 10% V; 50Hz
 

Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.