Sand - Falling Testing Machine for Motorcycle Helmets - Qinsun
Специализированные производители контрольно - измерительных приборов
Национальная & quot; горячая линия & quot;:+86 021-64208466
Продукты

Sand - Falling Testing Machine for Motorcycle Helmets

Main PurposesIt is mainly used to test the abrasion - resistance of the lenses of helmet goggles

WhatsApp: +86 13816217984

Email: info@qinsun-lab.com

Содержание

Main Purposes

It is mainly used to test the abrasion - resistance of the lenses of helmet goggles and evaluate their ability to resist particle - induced damage.


Applicable Standard

ASTM D968-83

JG/T 133-2000


Instructions for use:

1. according to the standard requirements for the preparation of test plates and placed in (23 +-2) degrees Celsius, relative humidity (50 +-5) degrees Celsius conditions for 24 hours.

2. Calibrate the apparatus:

Pour a certain amount of sand into the funnel, check the sand stream falling from the lower end of the conduit, and calibrate the device with the bottom adjusting screw until the inner part of the sand beam falls exactly on the center of the sand stream when viewed from two positions of 90 degrees Celsius each other. Use the high and low adjusting nut to adjust the distance from the tube tube to the painted surface according to the ASTM standard, when measured in the vertical direction, the near point of 1 inch (25mm), the user needs to be adjusted according to the thickness of their own samples, factory machine pre-adjustment of 25mm. to the pouring of a certain volume amount of sand (to 2000 +-10ml is appropriate), and measure the outflow time, the outflow rate should be 21S- 23.5S within 2L. This speed comes from the ASTM standard, and with the international standard sand for the test, we measured the speed of 1 minute 7L or more.

3. do the test should pay attention to, after the end of the sand fall, the machine should be slightly tilted to make the lower funnel in the small square of excess sand poured out, in the re-insertion of the sand fall switch in order to avoid the sand fall switch can not be put in.


Main Technical Parameters:

Overall Dimension: 230mm×200mm×1500mm (L×W×H)

Catheter Length: 36 inches (914mm)

Catheter I.D.: 0.75 inches (19mm)

Hopper Volume: 3L

Machine Weight: 25KG

image.png

Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.