Instrument ModelInstrument NameMain FunctionsHardware DifferencesTest TemperaturesRoutine Configurat
Электронная почта: info@standard-groups.com
Instrument Model | Наименование прибора | Основные функции | Разница в оборудовании | Test Temperatures | Routine Configurations (Number of Analysis Positions) | Commonly Tested Materials |
---|---|---|---|---|---|---|
Стандарт - 660 | Анализатор площади поверхности и апертуры | Adsorption analysis at liquid nitrogen temperature 77K, such as BET specific surface area analysis, meso-pore volume and pore size analysis. | Oil pump, single-stage pressure sensor, solenoid valve, P/P0 lower limit better than E-5 | Standard: 3L Dewar flask, liquid nitrogen 77K, liquid argon 87K | A3S, A6S, A3S, B3S, A6S, B6S | Non-porous materials such as lithium battery materials, inorganic salts, oxides, hydroxides, metal powders, organic materials |
Стандарт - 660 м | Расширенный анализатор площади поверхности и микропористости | Including functions of 660S, supports micropore analysis at 87K/Ar, 195K/CO2. etc., with micropore volume and pore size analysis capabilities. | Compared to 660S, configured with molecular pump, multi-stage pressure sensor, gas-controlled diaphragm valve and other micropore configurations, P/P0 lower limit better than E-9 | Standard: 3L Dewar flask, constant temperature circulating bath, -10℃~80℃ | 3 м, 6 м, 6с, 3м, 6м, 3м, 3м, 3м, 3м, 1м, 6м | Porous materials such as zeolite molecular sieves, activated carbon, MOF, COF, HOF, porous carbon, silica gel |
Стандарт - 660MG | усовершенствованный газосорбционный микропористый анализатор | Including functions of 660M, fully automatic continuous adsorption analysis for various gases and multiple temperature points, and fully automatic cycle adsorption lifetime evaluation. | Compared to 660M, configured with automatic multi-channel intake module and constant temperature bath communication function, multi-channel gas automatic switching, automatic flushing, automatic adsorption temperature switching. | Same as above | 3 мг, 6 мг, 6 сек / B3MG, 3 мг / B3MG, 6 мг / B6MG | - |
Стандарт - 660MC | усовершенствованный анализатор микропористости адсорбции коррозионных газов | Including functions of 660MG, with adsorption analysis capabilities for corrosive gases such as NH3. SO2. BF3. | Compared to 660MG, pipelines, valves, pressure sensors, sealing materials, etc., have stronger corrosion resistance, and equipped with corrosive adsorbate enrichment device. | Same as above | A3MC, A6MC, A3MG | - |
Стандарт - 660MV | Анализатор адсорбции пара / газа и микропористости (объемный метод) | Including functions of 660MG, with adsorption analysis capabilities for water vapor and organic vapors. | Compared to 660MG, a vapor adsorption module is added, equipped with a vapor enrichment device to reduce vapor contamination of pump oil. | Same as above | A3MV, A6MV, A3MG|B3MV, A3MC|B3MV | - |
◆ Full-functional: Specific surface area, mesopore, and micropore analysis;
◆ High-throughput: Optional analysis stations (3/6/9/12);
◆ Fully automatic: Degassing → Testing, fully automatic switching;
◆ Anti-contamination: "Pressure-controlled heating" for micropore sample degassing to prevent contamination;
◆ Zero helium contamination: Pre-heating zone with helium gas, followed by automatic degassing;
◆ Auto-cycling: Automatic evaluation of material cyclic adsorption performance.
Technical Parameter◆ Broad testing range: Specific surface area ≥0.0005 m²/g, pore size 0.35-500 nm;
◆ Testing efficiency: Multi-point BET (excluding degassing process), standard mode 12 samples/60 min; rapid testing mode 12 samples/15 min;
◆ High testing accuracy: Quantitative error of specific surface area, pore size, pore volume, and adsorption capacity <0.5% RSD (based on standard sample BET value);
◆ Temperature-programmed degassing: Software-controlled temperature programming, room temperature to 400°C, accuracy better than 0.1°C;
◆ Intelligent degassing completion judgment: Software-supported automatic judgment based on pressure changes to evaluate degassing effectiveness;
◆ Anti-dust degassing: Pressure-controlled heating + pressure-controlled vacuuming to completely eliminate sample dusting during degassing;
◆ Vacuum level: 10⁻² Pa;
◆ High reliability: International supplier system, core components imported with original packaging.
◆ High-throughput and high-efficiency
Поддержка анализа до 12 образцов одновременно;
◆ Truly fully automated
International first: automatic switching between degassing furnace and Dewar cup, no manual transfer of sample tubes or degassing furnace required;
◆ High time utilization
Solves the time waste issue of conventional instruments where degassing is completed after work hours, but testing cannot start. Enables sample loading after work and data viewing the next day;
◆ Complete elimination of "helium contamination"
Pioneering solution in the international arena: helium gas dead volume test → vacuum heating degassing → adsorption test, improving test accuracy by addressing the helium contamination challenge in micropore analysis;
◆ Anti-dust degassing
Supports "pressure-controlled heating" + "pressure-controlled vacuuming", automatically adjusting temperature programming and vacuuming rate based on pressure changes to prevent sample dusting;
◆ Supports automatic cycle testing
Automatic degassing + testing cycle for evaluating material adsorption performance stability and adsorption lifespan;
◆ "Pressure-controlled heating" sample pore protection technology (compliant with international standard ISO 9277:2022)
A temperature programming technique under gas pressure control, automatically starting and stopping temperature programming based on pressure changes to prevent excessive gas release and damage to sample pores (a common issue with micropore samples. Once pore damage occurs, it is difficult to detect and is a major source of instability in micropore sample test results).
◆ "Automatic constant temperature zone" patented technology
The curve shows that the 24-hour change rates of the "adsorption chamber equivalent volume" under three constant temperature zone methods are: BSD temperature zone servo automatic constant: 0.10%, isothermal clamp: 0.25%, liquid level sensor: 0.55%
◆ Convenient installation and sealing
Single analysis station with one-time sealing technology for 6 sample tubes, no need to seal each tube individually, providing unparalleled efficiency;
◆ Fully constant temperature gas path system
The internal gas path system of the instrument is fully constant temperature up to 40°C, with accuracy better than ±0.01°C;
◆ Upward-opening door
Humanized and easy to open and close, saving laboratory space;
◆ Electric turbo liquid nitrogen pump
Humanized liquid nitrogen addition, stepless speed regulation, free movement, safe and convenient, no liquid nitrogen contamination;
◆ Открытый интерфейс данных
The software can be integrated with LIMS to upload test results to LIMS.
Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.
Телефон компании
+86-21-6420 0566
Время работы
С понедельника по пятницу
Мобильный телефон:
13816217984
Электронная почта:
info@qinsun-lab.com