Main PurposeIt is mainly used for the extremely high - temperature pre - treatment of safety helmets
Электронная почта: info@standard-groups.com
Main Purpose
It is mainly used for the extremely high - temperature pre - treatment of safety helmets.
Compliance Standard
GB/T2812-2019
Технические параметры
1. Test chamber temperature: Room temperature - 200°C, with the standard operating temperature being 150±5°C. 2. Test time: 0 - 99 minutes, adjustable, with the standard being 60±2 minutes. 3. Number of test samples: 1 - 4 helmets. 4. Head mold temperature: 50°C±2°C. 5. Test head mold: Wall thickness > 1.5mm, size according to No.1 in GB2812, made of aluminum alloy with a hollow interior. 6. Temperature - measuring point of the head mold: The distance from the mid - point of the head mold is < 40mm. 7. Instrument dimensions: 870*710*1100mm
Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.