Main Uses of the Catheter Flow TesterThe catheter flow tester is mainly used to measure and evaluate
Электронная почта: info@standard-groups.com
Main Uses of the Catheter Flow Tester
The catheter flow tester is mainly used to measure and evaluate the flow performance of medical catheters, such as intravascular catheters, non - intravascular catheters, and infusion set catheters. In the medical field, this tester has a wide range of applications, including but not limited to the following aspects: - **Product R & D**: During the design and R & D stage of catheter products, the tester can help engineers accurately assess the flow performance of different design schemes, providing powerful data support for product iteration. - **Quality Control**: Through batch testing, the tester can ensure that each batch of catheters meets the established flow standards and performance requirements, thus improving the overall quality of products. - **Clinical Application**: The tester can be used to monitor the flow changes of catheters in patients, providing real - time physiological parameter feedback to doctors, which is helpful for adjusting treatment plans, assessing the progress of the disease, and preventing complications.
Критерии соответствия
GB/T 15812.1 - 2005 *Non - Vascular Intravascular Catheters - Part 1: General Performance Test Methods* YY 0285.1 - 2017 *Disposable Sterile Intravascular Catheters*
Технические параметры
- **Testing Range**: Usually within a certain weight or volume range, such as 1.00 - 600.00g (varying according to catheter specifications) or a specific flow range. - **Accuracy**: The testing accuracy is usually high, such as ±0.01%F.S. (one - ten - thousandth of the full scale) or higher accuracy requirements. - **Static Water Level Height**: Such as 200±5mm and 1000±5mm, etc., to meet different testing needs. The water pump has an automatic circulation function, and the static water level is adjustable. - **Time Controller**: Usually 0 - 60min, with an error not exceeding ±1S, used to control the testing time. - **Fixtures**: Can adapt to catheters of various specifications and types, ensuring the versatility and flexibility of the test. - **Flow Calculation**: Generally, the weighing method is used to calculate the flow (imported flowmeters can also be selected), to ensure the accuracy of the results. - **Flow Rate**: Such as 525ml/min (arbitrary selection) ±25ml/min, etc., to adapt to different testing scenarios. - **Intelligent Temperature Control**: The tester is usually equipped with a micro - computer intelligent temperature - control system to ensure the constancy and accuracy of the test temperature. - **Special Accessories**: Including stainless - steel thermostatic water baths, special connectors, etc., to meet the testing needs of catheters of different specifications and types.
Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.
Телефон компании
+86-21-6420 0566
Время работы
С понедельника по пятницу
Мобильный телефон:
13816217984
Электронная почта:
info@qinsun-lab.com