Специализированные производители контрольно - измерительных приборов
Национальная & quot; горячая линия & quot;:+86 021-64208466
Продукты

Double Plate Thermal Conductivity Apparatus

Double plate thermal conductivity tester integrated water bath thermostat equipment, all measurement

Электронная почта: info@standard-groups.com

Содержание

Double plate thermal conductivity tester integrated water bath thermostat equipment, all measurement and control are used computer control. Mainly testing plastic, rubber, glass, fiberboard, benzene board, extruded board, foam concrete, hollow glass, wood, all kinds of insulation materials such as homogeneous plate material, and can measure the pellets, bulk materials, soft materials and other Thermal conductivity of matter. The instrument can be widely used in heat and insulation materials production enterprises, the relevant quality inspection departments and units, institutions of higher learning and research institutes and other scientific research units.
 
image.png
Стандарты
GB/T 10294-2008  Determination of Steady State Thermal Resistance and Related Properties of Thermal Insulation Materials
GB/T 3399-1982   Test method for thermal conductivity of plastics - Heat - resistant plate method
GB/T 10801.1-2002  Thermal insulation polystyrene foam
GB/T 10801.2-2002   Extruded polystyrene foam
GB/T 3139-2005        Test method for thermal conductivity of fiber reinforced plastics
GB/T 17794-2008      Flexible foam rubber and plastic insulation products

Характеристики
Chassis is nice. Test box shell uses spray method. It has strong mechanical strength, anti-corrosion
The device is small and the unique casters are designed to increase the flexibility of the thermometer movement.
High safety performance. It not only adopts the use of circuit and refrigeration cycle independent design, but also can ensure that the electrical part of the collected data from the impact of water, and improve stability.
Good performance of temperature stability and unique protection board design, can form a one-dimensional protection, so that it has no loss of temperature.
Online double standard company unique technology which can calibrate the temperature, calibration system error, is accurate, fast and convenient.
 
Технические параметры

ПроектыПараметры
Specimen standard size300mm × 300mm × H (5 ~ 40) mm
Specimen flatness0.1mm
Thermal conductivity measurement display range (0.001 ~ 2.000) W / (m • K)
Thermal conductivity measurement accuracy± 3%
Thermal conductivity measurement Repeatability± 1%
Temperature resolution0.01 ℃
Temperature control accuracy0.05 ℃


Технические параметры

Different types of thermal conductivity tester temperature measurement rangeМодельCold plate temperature control interface ℃Hot plate temperature control range ℃
IMDRY3001-IRoom temperature - 95 ℃Room temperature - 100 ℃
IMDRY3001-Ⅱ-℃ -5 ℃ - 95 ℃15 ℃ - 95 ℃
IMDRY3001-Ⅲ-10 ℃ - 95 ℃10 ℃ - 95 ℃
IMDRY3001-IV-15 ℃ - 95 ℃5 ℃ - 95 ℃
IMDRY3001-V-20 ° C - 95 ° C0 ° C - 95 ° C
IMDRY3001-Ⅵ    -30 ℃ -95 ℃-10 ℃ -95 ℃
IMDRY3001-VII-40 ℃- 95 ℃ -20 ℃ - 95 ℃
Power supplyAC 220V ± 10%, 2.5KW
Specimen thicknessStandard 25mm, range (5 ~ 40) mm
Specimen thermal resistance requirementsthe thermal resistance of the specimen should not be less than 0.1 (m2 • K) / W, and should meet the thickness of the standard thickness Requirements; if the lower limit of thermal resistance of the specimen is as low as 0.02 (m2 • K) / W, the accuracy does not necessarily meet the requirements.
Clamping forceNo more than 2.5kPa

Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.


Онлайн сообщение

Контактные данные

Телефон компании

+86-21-6420 0566

Время работы

С понедельника по пятницу

Мобильный телефон:

13816217984

Электронная почта:

info@qinsun-lab.com

QR-код