Detailed Product DescriptionSulfur Measurement Range:0.0017% ~ 5%; 1%-80% (two Options)Measurem
WhatsApp +86 13816217984
Электронная почта :info@qinsun-lab.com
Sulfur Measurement Range: | 0.0017% ~ 5%; 1%-80% (two Options) | Measurement Time: | 60-180 Seconds |
---|---|---|---|
Single Sample Automatic Measurement, Measurement Repetition Times: | 1. 2. 3. 5. 10 Arbitrary Setting, The End Of The Measurement To Give The Average And Standard Deviation | Repeatability (r): | < 0.4347 X0.6446 (X= The Average Of Two Repeated Test Results) |
Reproducibility (R): | < 1.9182 X0.6446 (X= The Average Of Two Single, Independent Test Results) | Sample Size: | 5ml ~ 6ml |
Storage: | Can Store 10 Calibration Curves | Working Conditions: | Temperature :10 ~ 30℃; Relative Humidity :≤85% (30℃) |
Power Supply: | AC100-220V/50Hz; Rated Power :50W | Size And Weight: | 460mm*260mm*260mm; 11kg |
Highlight: | ASTM D 4294 Oil Testing Equipment X-ray fluorescence sulfur analyzer ASTM D 4294 sulfur analyzer |
Energy dispersive X-ray fluorescence sulfur analyzer is a special analyzer based on energy dispersive X-ray fluorescence spectroscopy. The analyzer principle, design structure, instrument elements, analytical method operation flow, error and reproducibility all conform to GB/T 17040-2019 and ASTM D4294 for the determination of sulfur content in petroleum and petroleum products.
◆ Measuring sulfur content of crude oil, petroleum, heavy oil, diesel oil, kerosene, naphtha;
◆ Measuring the total sulfur content of coal chemical products, such as primary benzene;
◆ Measurement of sulfur content in other liquid or solid fine powder samples such as petroleum coke.
◆ Intelligent electromechanical integrated microcomputer design,8 inch wide viewing Angle capacitive touch screen (1024*768) display
◆ Wide detection variety, wide detection range, fast analysis speed, less standard sample consumption;
◆ The instrument has automatic peak stabilization function and automatic diagnosis function, monitoring the working state and electrical parameters of the instrument;
◆ Disposable Mylar film sample cup to avoid cross contamination; Sample cup production is convenient and fast;
◆ Accurate positioning of the sample table, easy to place the sample and replace the anti-oil leakage film, and avoid the possibility of contamination of the detection system;
◆ Large storage capacity of instrument data, 4096 content analysis results and 8192 count measurement data, 16 instrument calibration results.
◆ Thermal printer automatically prints test results;
◆ The instrument automatically selects the working curve without user intervention;
◆ The user can choose the measurement result unit, ppm or (m/m)%;
◆ Safe radiation protection measures, no harm to individuals and groups of ionizing radiation.
1. Sulfur measurement range: 0.0017% ~ 5%; 1%-80% (two options)
2. Measurement time: 60-180 seconds;
3. Single sample automatic measurement, measurement repetition times: 1. 2. 3. 5. 10 arbitrary setting, the end of the measurement to give the average and standard deviation;
4. Repeatability (r): < 0.4347 X0.6446 (X= the average of two repeated test results);
5. Reproducibility (R): < 1.9182 X0.6446 (X= the average of two single, independent test results);
6. Sample size :5ml ~ 6ml;
7. The instrument can store 10 calibration curves;
8. Working conditions: Temperature :10 ~ 30℃; Relative humidity :≤85% (30℃); Power supply :AC100-220V/50Hz; Rated power :50W;
9. Size and weight: 460mm*260mm*260mm; 11kg.
Вышеуказанный контент предназначен для ссылки и общения только между инсайдерами отрасли и не гарантирует его точности или полноты. Согласно соответствующим законам и нормативным актам и правилам этого веб-сайта, подразделения или лица, приобретающие связанные с ними предметы, должны получить действительную квалификацию и условия квалификации.
Телефон компании
+86-21-6420 0566
Время работы
С понедельника по пятницу
Мобильный телефон:
13816217984
Электронная почта:
info@qinsun-lab.com